| Sign In | Join Free | My portofva.com | 
 | 
Brand Name : KACISE
Model Number : TDLAS200
Certification : CE
Place of Origin : china
MOQ : 1PCS
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 1000 Piece/Pieces per Week negotiable
Delivery Time : 5-8 work days
Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available
Product model : TDLAS200
Detection object : Methane (CH4)
Measurement principle : Laser absorption spectrum (TDLAS)
Volume : 53ml
Fastest response time : 0.1s
Measurement range : 0~5000ppm
TDLAS200 Auto-Calibrating Laser Methane Sensor
1.Introduction
The KACISE TDLAS200 Auto-Calibrating Laser Methane Sensor is designed for hassle-free and accurate methane detection. It features a built-in reference cell for automatic calibration, ensuring consistent performance over time. With a detection range of 0~5000ppm and a response time of 0.1 seconds, it provides reliable data for safety and environmental monitoring. The sensor is compact and easy to integrate, with an operating temperature range of -20~50℃. KACISE combines advanced TDLAS technology with user-friendly features for superior methane detection.
 
 2.Features
3.Measuring Principle
 
 "Methane molecules absorb light of a specific wavelength" --Molecular absorption spectrum
 "The amount of light absorbed by a transparent medium (methane gas mass) is proportional to the thickness and concentration of the gas mass" --Beer-Lambert's law
 According to the above physical principles, a beam of light of a specific wavelength can be used to penetrate the leaking methane gas mass. According to the degree of weakening of the beam, the concentration of methane in the gas mass can be measured, and it only responds to methane (unique selectivity).
 Using a detection cell with multiple reflections and allowing the laser to repeatedly pass through the gas being measured can multiply the detection sensitivity.
 
| Product model | TDLAS200 | 
| Detection object | Methane (CH4) | 
| Measurement principle | Laser absorption spectrum (TDLAS) | 
| Static detection limit | 0.5ppm@25℃10SPS (typical value, please contact us for details) | 
| Volume | 53ml | 
| Fastest response time | 0.1s | 
| Measurement range | 0~5000ppm | 
| Measurement deviation | 0-200ppm true value +/-2ppm 200-1000ppm true value +/-1% 1000-5000ppm true value +/-2% | 
| 12hrs drift | +/-1.5ppm | 
| Operating temperature | -20~50℃ | 
| Power supply | 5-12VDC 1W (typical) 3W (maximum) | 
| Dimensions and weight | 115×59×38mm | 
| Gas interface | Pagoda direct M-5AU-4 | 
| Fastest response time | Detection time 0.1s | 
*1 Please ensure that the power input voltage of the module is not less than 5V
*2 Pump selection recommendation <500ml/min
Dimensions of the detection module host: 115×59×38mm (excluding cables and gas connectors)

|   | 
| TDLAS200 Auto-Calibrating Laser Methane Sensor Images | 
 Highly T90≤30s Response Time Refrigerant Gas Sensor KGD-AM-204 with RS485 Modbus
                                                                                    
                        
                        
                        
                                                            Highly T90≤30s Response Time Refrigerant Gas Sensor KGD-AM-204 with RS485 Modbus
                                                    
                        
                     KFK - G60 - TSP Factory Dust Surveillance Pro
                                                                                    
                        
                        
                        
                                                            KFK - G60 - TSP Factory Dust Surveillance Pro
                                                    
                        
                     M20*1.5 Mounting Thread Nitrogen Oxide Sensor KGD 325 For Diesel Vehicle
                                                                                    
                        
                        
                        
                                                            M20*1.5 Mounting Thread Nitrogen Oxide Sensor KGD 325 For Diesel Vehicle
                                                    
                        
                     R1234ZE Refrigerant Leakage Monitoring Sensor KGD-AM-205 Non-dispersive Infrared
                                                                                    
                        
                        
                        
                                                            R1234ZE Refrigerant Leakage Monitoring Sensor KGD-AM-205 Non-dispersive Infrared
                                                    
                        
                     KFK - G60 Flammable Gas Sentinel
                                                                                    
                        
                        
                        
                                                            KFK - G60 Flammable Gas Sentinel
                                                    
                        
                     Wide - Range Oxygen Sensor KGD - 324
                                                                                    
                        
                        
                        
                                                            Wide - Range Oxygen Sensor KGD - 324
                                                    
                        
                     Refrigerant (R744) Leakage Monitoring Sensor KGD - AM - 206
                                                                                    
                        
                        
                        
                                                            Refrigerant (R744) Leakage Monitoring Sensor KGD - AM - 206
                                                    
                        
                     Laser Scattering Sampling Method Industrial Dust Guardian KFK-G60-TSP with DC24V
                                                                                    
                        
                        
                        
                                                            Laser Scattering Sampling Method Industrial Dust Guardian KFK-G60-TSP with DC24V
                                                    
                        
                     Limiting Current - Type Oxygen Sensor KGD - 323
                                                                                    
                        
                        
                        
                                                            Limiting Current - Type Oxygen Sensor KGD - 323
                                                    
                        
                     KGD OPC 201 28.3L Particle Counter with Multi channel Counting Efficiency of 50%
                                                                                    
                        
                        
                        
                                                            KGD OPC 201 28.3L Particle Counter with Multi channel Counting Efficiency of 50%