Proline Promass O 500 Coriolis flowmeter

Brand Name : Endress+Hauser

Certification : CE

Model Number : Proline Promass O 500

MOQ : 1pcs

Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram

Supply Ability : 1000 Piece/Pieces per Week negotiable

Delivery Time : 5-8 work days

Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available

Measuring range : 0 to 2 200 000 kg/h (0 to 80 850 lb/min)

Max. process pressure : PN 250, Class 1500

Medium temperature range : –40 to +205 °C (–40 to +401 °F)

Ambient temperature range : Standard: –40 to +60 °C (–40 to +140 °F)

Contact Now

"Specs at a glance
Max. measurement error
Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³

Measuring range
0 to 2 200 000 kg/h (0 to 80 850 lb/min)

Medium temperature range
–40 to +205 °C (–40 to +401 °F)

Max. process pressure
PN 250, Class 1500

Wetted materials
Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750)
Connection: 25Cr duplex (Super Duplex), 1.4410 (F53)" "Field of application
Promass O is designed for premium accuracy of liquids and gases at the highest process pressures in the oil and gas industry. The sensor is fully suitable for offshore conditions and resistant to stress corrosion cracking. With its innovative remote transmitter Promass O 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables safe processes.

Measuring principle operates independently of physical fluid properties such as viscosity or density

For premium accuracy at highest process pressures, fully suitable for offshore conditions


Device properties

Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750)

Process pressure up to PN 250 (Class 1500)

Nominal diameter: DN 80 to 250 (3 to 10"")

Remote version with up to 4 I/Os

Backlit display with touch control and WLAN access

Standard cable between sensor and transmitter" "Benefits
Maximum safety – highest resistance to stress corrosion cracking

Fewer process measuring points – multivariable measurement (flow, density, temperature)

Space-saving installation – no in-/outlet run needs

Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet

Reduced complexity and variety – freely configurable I/O functionality

Integrated verification – Heartbeat Technology" "Measuring principle
Coriolis

Product headline
Robust high-pressure flowmeter, as remote version with up to 4 I/Os.
For premium accuracy at highest process pressures, fully suitable for offshore conditions.

Sensor features
Maximum safety – highest resistance to stress corrosion cracking. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Measuring tube in 25Cr Duplex, 1.4410 (UNS S32750). Process pressure up to PN 250 (Class 1500). Nominal diameter: DN 80 to 250 (3 to 10"").

Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.

Nominal diameter range
DN 80 to 250 (3 to 10"")

Wetted materials
Measuring tube: 25Cr duplex (Super Duplex), 1.4410 (UNS S32750)
Connection: 25Cr duplex (Super Duplex), 1.4410 (F53)

Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow (API tables), reference density, concentration

Max. measurement error
Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³

Measuring range
0 to 2 200 000 kg/h (0 to 80 850 lb/min)

Max. process pressure
PN 250, Class 1500

Medium temperature range
–40 to +205 °C (–40 to +401 °F)

Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)

Sensor housing material
1.4404 (316L), highest corrosion resistance
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L

Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat

Degree of protection
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure

Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible

Outputs
4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output

Inputs
Status input
4-20 mA input

Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC

Product safety
CE, C-tick, EAC marking

Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
MI-005 Liquids other than water (Hydrocarbons), Cryogenic Liquids, LPG
OIML R117 Liquids other than water, Cryogenic Liquids, LPG
MI-002, PTB

Marine approvals and certificates
LR approval, DNV approval, ABS approval, BV approval, CCS approval

Pressure approvals and certificates
PED, CRN, AD 2000

Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK"


Product Tags:

Proline Promass O 500 flowmeter

      

Coriolis flowmeter with warranty

      

Electromagnetic flow meter industrial

      
China Proline Promass O 500 Coriolis flowmeter wholesale

Proline Promass O 500 Coriolis flowmeter Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)