Sign In | Join Free | My portofva.com
China Xi'an Kacise Optronics Co.,Ltd. logo
Xi'an Kacise Optronics Co.,Ltd.
Kacise, understanding your automation needs.
Verified Supplier

8 Years

Home > Electromagnetic Flow Meter >

Dosimag electromagnetic flowmeter

Xi'an Kacise Optronics Co.,Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Dosimag electromagnetic flowmeter

Brand Name : Endress+Hauser

Certification : CE

Place of Origin : Switzerland

MOQ : 1PCS

Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram

Supply Ability : 1000 Piece/Pieces per Week negotiable

Delivery Time : 5-8 work days

Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available

Max. measurement error : ±0.25 % o.r. ± 1 to 4 m/s (3.3 to 13 ft/s)

Measuring range : 0.14 to 1.66 l/s (0.035 to 0.44 gal/s)

Medium temperature range : Seal material EPDM: –20 to +130 °C (–4 to +266 °F)Seal material Silicone: –20 to +130 °C (–4 to +266 °F)Seal material Viton: 0 to +150 °C (+32 to +302 °F)

Max. process pressure : PN 16

Wetted materialsLiner : PFAElectrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022), Tantalum,Platinum

Transmitter housing material : 1.4404 (316/316L)

Contact Now

"Specs at a glance
Max. measurement error
±0.25 % o.r. ± 1 to 4 m/s (3.3 to 13 ft/s)
Measuring range
0.14 to 1.66 l/s (0.035 to 0.44 gal/s)
Medium temperature range
Seal material EPDM: –20 to +130 °C (–4 to +266 °F)
Seal material Silicone: –20 to +130 °C (–4 to +266 °F)
Seal material Viton: 0 to +150 °C (+32 to +302 °F)
Max. process pressure
PN 16
Wetted materials
Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022), Tantalum,
Platinum
See all specifications" "Field of application
Dosimag is designed for demanding filling and bottling applications with conductive liquids in Food & Beverage and Life Sciences. In applications where space is limited, Dosimag is the preferred choice for system integrators, skid builders and equipment manufacturers. Dosimag measures volume directly. The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity.
The compact and robust sensor is available with three electronics versions:
Pulse/frequency/status version for easy and economical use in filling applications
Intelligent pulse version with IO-Link provides continuous digital communication, allowing easy commissioning and documentation, real-time availability of process data, optimization of filling conditions and predictive maintenance
Integrated batching version with Dynamic Drip Correction over Modbus RTU for advanced filling control" "Benefits
High and stable filling performance – high measuring accuracy and repeatability in shortest filling times
IO-Link allows real-time digital communication for easier commissioning and continuous data availability
Compact design for optimized machine footprint
Integrated batching functionality – filling process management solved by the flowmeter
Automatic recovery of data for servicing
Global compliance with industry standards – EHEDG, 3-A, FCM, cGMP
SIP and CIP cleanable" "Measuring principle
Electromagnetic
Product headline
Flowmeter with hygienic design, highest repeatability and an ultra-compact sensor.
For demanding dosing and filling applications.
Sensor features
High process safety – high measuring accuracy and repeatability in shortest filling time. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Wetted materials CIP, SIP cleanable. Nominal diameter: DN 4 to 25 (¹⁄₈ to 1). Measuring device conform to FDA.
Transmitter features
Versatile and time-saving wiring – plug connector. Industry-optimized – ultra-compact design. For hygienic requirements – stainless steel housing.
Pulse/frequency/switch output, Modbus RS485. Custody transfer approvals (MID, NTEP). Excellent, easily cleanable transmitter.
Nominal diameter range
DN 4 to 25 (¹⁄₈ to 1)
Wetted materials
Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022), Tantalum,
Platinum
Measured variables
Volume flow, Temperature (DN15-26)
Max. measurement error
±0.25 % o.r. ± 1 to 4 m/s (3.3 to 13 ft/s)
Measuring range
0.14 to 1.66 l/s (0.035 to 0.44 gal/s)
Max. process pressure
PN 16
Medium temperature range
Seal material EPDM: –20 to +130 °C (–4 to +266 °F)
Seal material Silicone: –20 to +130 °C (–4 to +266 °F)
Seal material Viton: 0 to +150 °C (+32 to +302 °F)
Ambient temperature range
–40 to +60 °C (–40 to +140 °F)
Sensor housing material
1.4404 (316/316L)
Transmitter housing material
1.4404 (316/316L)
Degree of protection
IP66/67, type 4X enclosure
Display/Operation
No local Operation
Configuration via operating tools possible
Outputs
Pulse/frequency/switch output (passive)
Inputs
None
Digital communication
Modbus RS485, IO-Link
Power supply
DC 20 to 30 V
Hazardous area approvals
ATEX, UL, UK Ex
Product safety
CE
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc.to ISO/IEC 17025)
NTEP
Material certificates
3.1 material
Hygienic approvals and certificates
Sanitary approval: 3-A, EHEDG, seals acc. to FDA"

Product Tags:

Dosimag electromagnetic flow meter

      

electromagnetic flow meter with warranty

      

industrial electromagnetic flow meter

      
China Dosimag electromagnetic flowmeter wholesale

Dosimag electromagnetic flowmeter Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)